| Grouting | |
Chemical
grouting is a very cost effective method to
stop infiltration into leaking pipes and structure walls identified
during the inspection
process. Either Acryladmide, Acrylic, or Urethane types of grout can
be used depending upon the application. For pipe joint grouting, a
packer device is winched into place over the joint using a closed circuit
camera to line up, and the packer is then remotely inflated to test
and/ or seal the joint. Large diameter pipes and structures can be
grouted by drilling injection points and then pumping the chemical
grout outside to seal the leaks.
| |
| "STATE OF THE ART EQUIPMENT" |
|